Suppliers with verified business licenses
Model | LS-25-5 | LS-25-12 | LS-25-15 | LS-15-24 | |||||
Output | DC Voltage | 5V | 12V | 15V | 24V | ||||
Voltage Tolerance | ± 2% | ± 1% | ± 1% | ± 1% | |||||
Rated Current | 5A | 2.1A | 1.7A | 1.1A | |||||
Current Range | 0-5A | 0-2.1A | 0-1.7A | 0-1.1A | |||||
Rated Power | 25W | 25.2W | 25.5W | 26.4W | |||||
Ripple & Noise | 50mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |||||
DC Adjustment Range | -5%,+10% | ± 10% | ± 10% | ± 10% | |||||
Setup, Rise, Hold Time | 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC at full load | ||||||||
Input | Voltage Range | 85-132VAC/170-264VAC 47-63Hz; Selected by switch 120-370VDC | |||||||
AC Current | 0.6A/115V 0.35A/230V | ||||||||
Efficiency | 72%/115VAC | 76%/115VAC | 77%/115VAC | 80%/115VAC | |||||
Inrush Current | Cold start 15A/115VAC 30A/230VAC | ||||||||
Leakage Current | Less than 0.75 mA/240VAC | ||||||||
Protection | Over Load | 110%-160% | |||||||
Protection type: Fold back current limiting, recovers automatically after fault condition is removed | |||||||||
Over Voltage | 115%-135% | ||||||||
Protection type: hiccup mode, recovers automatically after condition is removed. | |||||||||
Environment | Working Temp., Humidity | -10 ° C- +60 ° C; 20%-90% RH | |||||||
Storage Temp., Humidity | -20 ° C- +85 ° C;10%-95 RH | ||||||||
Vibration | 10-500Hz,2G 10min./1cycle, period for 60 min, X, Y, Z each along axes | ||||||||
Safety | Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||||||||
Standard | Safety Standard | Design refer to UL1012, TUV EN60950 | |||||||
EMC Standard | Design refer to EN55022, EN61000-3-2, -3, EN61000-4-2, 3, 4, 5 ENV50204, EN55024 | ||||||||
Others | Weight | 0.39Kg | |||||||
Dimensions | 99*97*36mm(L*W*H) |